Salt water spray test device: This device is used to test the surface treatment
of various materials. The so-called treatments include coating, coating
electroplating films of organic and non-organic materials, anodizing, anti-rest oil
and corrosion resistant treatment, which may achieve the purpose of keeping the
items from being corroded for a longer period.
* Specification:
o TEST APPLIACABLE: NSS , ACSS , CASS.
o TEST TEMPERATURE: 35!O1¢J or 50!O1¢J.
o INSIDE DIMENSION: 450 x 600 x 400 (DxWxH)m/m.
o OUTSIDE DIMENSION: 760 x 1140 x 1190 (DxWxH)m/m.
o VOLUME: 108 LITER.
o WEIGHT: 60 KGW.
o TEST SPECIMEN
o 15¢X: 24 PCS.
o TEST SPECIMEN
o 30¢X: 15 PCS.
o SOLUTION TANK CAPACITY: 15 LITER.
o SOLUTION TANK TESTING TIME: 90 HR.
o POWER CONSUMPTION: 220V SINGLE PHASE 3KW.
* Features:
o A. The whole part of the device is made of P.V.C. sheet and the inside of the
o device is reinforced by using a special lining material. Hence, it is sturdily
o made and will not transform forever.
o B. The test chamber is heated from five directions in order to ensure the
o temperature difference in the chamber may be kept within(+)(-)1 Celsius
o degree.
o C. Spray nozzle: The nozzle is specially made to enable it to suck up the salt
o Water and then spray it out in the shape of mist with considerable high
o speed. When it falls on the surface of the item being tested , the difference
o of fallen mist may be controlled within(+)/(-)0.3ml per 80 square centimeter
o H.
o D.HUNTER PRINCIPLE is used to make the saturated air hot and moist and to
o keep the humidity in the test chamber required for test.
o E. Temperature is the pre-requisite condition that will have direct impact on
o corrosion rate . We use P.I.D. temperature control unit to limit the
o temperature difference within the range of (+)(-)0.5 Celsius degree.
o F. A warning device is used to indicate the low level of the test fluid. When the
o fluid is only enough for being sprayed for five hours , a buzzer will remind the
o user to replenish the liquid to ensure continuous spray test.
o G. Digital Display Time Controller!G9.9S-9990HR ANLY AH5R
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Reviews
There are no reviews yet.