Product applications: | ||
Work with every kind of applications of AC induction motor. | ||
The Variable Frequency Drive is suitable for any general-purpose application that involves a AC motor, has full of operation functions. Built-in variable digital/analog input functions to meet a wide variety of needs. Adlee’s variable frequency inverter is easy to install and convenient to humanity operating features
|
Variable Frequency Drive
1. | New Technology Super Low Noise |
Innovative soft/hard ware. optimum waveform. The motor as quiet as running with commercial power. | |
2. | All Model Equipped With IPM |
Employ IPM (intelligent power module) for power device. IPM provides numerous advantages such as quiet operation, high efficiency, high torque smoother shaft rotation and improved reliability. | |
3. | Expansion Of Frequency Range |
The range of variable frequency has been greatly extended from 0.5HZ-2400HZ. and S curve for smooth ACC/DEC. performance. | |
4. | Upgrading V/F Characteristic |
Provide constant torque curve (F1) reduce torque curve (F2) and (F3) for FAN/PUMP drive. Adjustable saving energy operation and wide basic voltage setting from 30HZ-2400HZ. Double V/F curve performance. | |
5. | Enhanced I/O Function |
Built-in variable digital/analog input functions and RS-485 communication to meet a wide of variety of needs, then our VFD is easy to install and convenient humanity operating features. | |
6. | Compact Structure |
Adlee AC drive’s compact size design makes installation easier, it solves space limited problem. | |
7. | Extended Braking Resistor Available |
All series with extended braking resistor terminals. It makes machine more reliable in high frequency switching RUN/STOP or High speed/Low speed situation. | |
8. |
Cycle Timing Function |
All series AC inverters are with cycle timing function for special purpose option. Not only cost decrease but also use friendly for Timer model replacing general purpose AC drive with PLC. |
|
|
MS Series | MS2 | MS4 | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | 1Φ 220VAC ± 10% | 3Φ 380/440VAC ± 10% | ||||||||||
Model No. | 102 | 104 | 107 | 115 | 122 | 137 | 307 | 315 | 322 | 337 | ||
Input Frequency | 50-60HZ ±10% | 50-60HZ ±10% | ||||||||||
Output Voltage | 3 Φ 220VAC | 3 Φ 380/440VAC | ||||||||||
Output Frequency | 0.5-1200HZ | 0.5-1200HZ | ||||||||||
|
1.4 | 2.5 | 4.1 | 7 | 10 | 16 | 2.5 | 4 | 6 | 9 | ||
|
0.6 | 1.0 | 1.6 | 2.7 | 3.8 | 6.1 | 1.9 | 3.1 | 4.2 | 6.9 | ||
|
0.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 0.75 | 1.5 | 2.2 | 3.7 | ||
Control Method | SIN WAVE PWM | SIN WAVE PWM | ||||||||||
Cooling Method | Self-Cooled | Air-Cooled | Air-Cooled | |||||||||
|
1.2 | 1.2 | 1.3 | 1.3 | 1.4 | 4 | 1.3 | 1.3 | 1.4 | 4 | ||
|
Fig.1 | Fig.1 | Fig.1 | Fig.2 | Fig.2 | Fig.3 | Fig.3 | Fig.5 | Fig.5 | Fig.3 |
|
AS Series | AS1-N | AS2-N | AS4-N | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | 1Φ 110VAC ± 10% | 1Φ 220VAC ± 10% | 3Φ 220VAC ± 10% | 3Φ 380/440VAC ± 10% | ||||||||||||||
Model No | 104 | 107 | 104 | 107 | 115 | 122 | 137 | 304 | 307 | 315 | 322 | 337 | 307 | 315 | 322 | 337 | ||
Input Frequency | 50-60HZ ±10% | 50-60HZ ±10% | 50-60HZ ±10% | 50-60HZ ±10% | ||||||||||||||
Output Voltage | 3 Φ 220VAC | 3 Φ 220VAC | 3 Φ 220VAC | 3 Φ 380/440VAC | ||||||||||||||
Output Frequency | 0.5-400HZ /(ASNH up to 2400HZ) | |||||||||||||||||
|
2.5 | 4.1 | 2.5 | 4.1 | 7 | 10 | 16 | 3 | 5 | 8 | 11 | 17 | 2.5 | 4 | 6 | 9 | ||
|
1.0 | 1.6 | 1.0 | 1.6 | 2.7 | 3.8 | 6.1 | 1.1 | 1.9 | 3.1 | 4.2 | 6.5 | 1.9 | 3.1 | 4.2 | 6.9 | ||
|
0.4 | 0.75 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 0.75 | 1.5 | 2.2 | 3.7 | ||
Control Method | SIN WAVE PWM | SIN WAVE PWM | SIN WAVE PWM | |||||||||||||||
Cooling Method | Self-Cooled | Air-Cooled | Self-Cooled | Air-Cooled | Self-Cooled | Air-Cooled | Air-Cooled | |||||||||||
|
1.2 | 1.3 | 1.2 | 1.3 | 1.3 | 1.4 | 4.2 | 1.2 | 1.3 | 1.3 | 1.4 | 4.2 | 1.3 | 1.3 | 1.4 | 4 | ||
|
Fig.4 | Fig.5 | Fig.4 | Fig.4 | Fig.5 | Fig.5 | Fig.3 | Fig.4 | Fig.4 | Fig.5 | Fig.5 | Fig.3 | Fig.5 | Fig.5 | Fig.5 | Fig.3 |
|
HS Series | HS2 | HS4 | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | 1Φ 110VAC ± 10% | 1Φ 220VAC ± 10% | 3Φ 380/440VAC ± 10% | |||||||||||||
Model No | 104 | 107 | 115 | 122 | 137 | 304 | 307 | 315 | 322 | 327 | 307 | 315 | 322 | 337 | ||
Input Frequency | 50-60HZ±10% | 50-60HZ±10% | 50-60HZ±10% | |||||||||||||
Output Voltage | 3 Φ 220VAC | 3 Φ 220VAC | 3Φ 380/440VAC | |||||||||||||
|
2.5 | 4.1 | 7.0 | 10 | 16 | 3.0 | 5.0 | 8.0 | 11 | 17 | 2.5 | 4.0 | 6.0 | 9.0 | ||
|
1.0 | 1.6 | 2.7 | 3.8 | 6.1 | 1.1 | 1.9 | 3.1 | 4.2 | 6.5 | 1.9 | 3.1 | 4.2 | 6.9 | ||
|
0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 0.75 | 1.5 | 2.2 | 3.7 | ||
Control Method | SIN WAVE PWM | SIN WAVE PWM | SIN WAVE PWM | |||||||||||||
Cooling Method | Self-Cooled | Air-Cooled | Self-Cooled | Air-Cooled | Air-Cooled | |||||||||||
|
1.2 | 1.3 | 1.3 | 1.4 | 4.2 | 1.2 | 1.3 | 1.3 | 1.4 | 4.2 | 1.3 | 1.3 | 4 | 4.0 | ||
|
Fig.9 | Fig.9 | Fig.10 | Fig.10 | Fig.3 | Fig.9 | Fig.9 | Fig.10 | Fig.10 | Fig.3 | Fig.10 | Fig.10 | Fig.10 | Fig.3 |
** HS series of variable frequency inverter is a special model for water pump application ** The water pressure sensor signal can input to drive directly. The water pump pressure can be set on panel. The AC inverter will adjust the motor speed automatically to have constant water pressure performance. |
|
AP4 Series | AP4G3 ・ AP4H3 | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | 3Φ 380/440VAC ± 10% | |||||||||||||
Model No | 337 | 355 | 375 | 3110 | 3150 | 3185 | 3220 | |||||||
Input Frequency | 50HZ / 60HZ ± 5% | |||||||||||||
Output Voltage | 3Φ 380/440VAC ± 10% | |||||||||||||
Output Frequency | 0.5HZ~400HZ (AP4H3 Up To 2400HZ) | |||||||||||||
|
8.5 | 12 | 16.5 | 23 | 31 | 38 | 45 | |||||||
|
6.5 | 9.2 | 12.6 | 17.6 | 23.6 | 29 | 34 | |||||||
|
3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |||||||
Control Method | SIN WAVE PWM | |||||||||||||
Cooling Method | Self-Cooled | Air-Cooled | Self-Cooled | |||||||||||
|
5.5 | 6.2 | 6.6 | 6.8 | 18 | 18.5 | 19.5 | |||||||
|
Fig.6 | Fig.7 |
|
AP2 Series | AP2G3 ・ AP2H3 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage | 3Φ 220VAC ± 10% | ||||||||||||
Model No | 337 | 355 | 375 | 3110 | 3150 | 3185 | 3220 | ||||||
Input Frequency | 50HZ / 60HZ ± 5% | ||||||||||||
Output Voltage | 3Φ 220VAC ± 10% | ||||||||||||
Output Frequency | 0.5HZ~400HZ (AP2H3 Up To 2400HZ) | ||||||||||||
|
17 | 24 | 33 | 46 | 61 | 76 | 90 | ||||||
|
6.5 | 9.2 | 12.6 | 17.6 | 23.6 | 29 | 34 | ||||||
|
3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | ||||||
Control Method | SIN WAVE PWM | ||||||||||||
Cooling Method | Self-Cooled | Air-Cooled | Self-Cooled | ||||||||||
|
5.5 | 6.2 | 6.6 | 17 | 18 | 18.5 | 19.5 | ||||||
|
Fig.6 | Fig.7 |